Seismic Fragility Analysis of Existing Old Newari Brick Masonry Building in Pokhara Valley

Abstract

Most of the building stock in Nepal is based on masonry construction, which includes monumental, administrative, and residential structures. These structures are vulnerable during earthquakes, as evidenced by the massive structural damage, loss of human life, and property damage due to a lack of proper assessment and appropriate strengthening measures. An analysis of the seismic vulnerability of existing old Newari brick masonry buildings in the Pokhara Valley is presented. These buildings were built using indigenous knowledge and technology. The investigation is based on analytical studies, with some material properties obtained from field tests. Proper modeling of a masonry structure is crucial for reliable seismic resistance and structural design. However, modeling a real masonry structure is a challenging and computationally demanding task due to its complicated framework, requiring in-depth knowledge, realistic material properties, and relevant information. The aim of this research is to assess the seismic performance of old Newari masonry buildings using stress level and fragility curves. The research issues are addressed analytically through linear time history analysis using the finite element program-based software Sap 2000 v20. In dynamic analysis, numerical building models were subjected to three synthetic earthquakes. The performance status of the building based on various stress levels is evaluated, and weak regions are identified. The fragility curve of the structure is assessed, considering the ground motion parameters in the locality. The fragility function is plotted with the probability of failure at an interval of 0.10 g. The results of the analysis highlight that the studied structure is vulnerable compared to the codal provisions and standard recommendations.

Full Text

1. Introduction Most of the historic, administrative, and residential building structures in Nepal are based on masonry construction. To date, more than 60 % of buildings in Nepal are masonry, which have heavy mass and low compressive strength, and these structures are normally up to four stories tall. They have a flexible diaphragm system both in the roof and floor levels. Basically, masonry structures are built with mortar and masonry units. The mortar is made with lime-cement, clay, and bitumen, while mud, stone, and fire clay are used as masonry units. However, the majority of the masonry buildings in Nepal are constructed without adopting proper engineering guidelines. In past seismic events, the masonry structures have failed due to inadequate brick units, poor quality of mortar, irregularities in plane and vertical direction, inadequate loadbearing walls, lack of vertical confinement, weak bottom storeys, wall openings, improper section and dimension, wall connections, etc. [1]. In fact, unreinforced masonry buildings are more vulnerable to earthquakes due to their heavy mass, insufficient deformation capacity, and lack of integrity between the structural elements [2]. These types of structures have a brittle failure mode during earthquakes (see Figure 1). a b c d e f Figure 1. Failure mode in masonry building during earthquake: a - separation of short wall at cross section; b - complete collapse of short wall; c - collapse of gable wall; d - out of plane bulging; e - in plane damage with opening; f - shear damage S o u r c e: photos by R.K. Adhikari, D.D’Ayala [3] Researchers [4; 5] studied the importance of compressive strength in conventional design practices, while in [6] highlighted the necessity of characterizing the mechanical behavior of masonry bond. Costigan et al. [7] and Parajuli and Kiyono [8] experimentally characterized the mechanical properties of masonry walls. Endo et al. [9] conducted an experiment on a brick masonry wall composed of fired bricks and mud mortar. Parajuli et al. [10] studied the behavior of the monumental brick masonry wallet through in-situ tests. The analysis of masonry structures is a challenging and computationally demanding task due to their complicated framework. It requires in-depth knowledge, realistic material properties, and relevant information. It is difficult to extract the structural and material properties of the structure built with indigenous technology in the absence of information and data concerning the behavior of their primary frameworks. The appropriate modeling technique is essential to extract the realistic response of old masonry structures. Creating a feasible model for a contemporary structure made of new industrial materials is easier, as materials and member properties are more uniform and largely clear. However, accounting for the multiple uncertainties of the problem that arise during the analysis and design of the structure requires more work. Nevertheless, there is negligible study found in the literature that covers both the characterization of the mechanical properties of masonry and performance assessment of such a historical building structure based on those properties. In the Pokhara valley, most of the masonry structures have existed for three to four generations without proper damage assessment, which ultimately leads to the loss of life and property. Proper strengthening measures can restore the existing buildings, which will have a greater impact on the overall performance of the structure. Realistic seismic performance evaluation methods should be followed for this purpose. To this end, this research focuses on the performance assessment of existing old historical building structures based on field data. The research objective is achieved through the analysis of numerical models. The numerical models are subjected to three earthquakes of Kobe, El-Centro, and Gorkha. Finally, the results are based on the stress level and fragility curves in different ground motions, and these are compared with standard codal provisions and recommendations. 2. Study of existing old Newari building 2.1. Description of building under study The prototype building structure is a traditional building in the locality that was constructed in the 17th century using original local technology. Most old Newari buildings in the area have traditional architecture. The building is three to four stories high with a floor height ranging from 1.8 to 2.3 meters and a larger opening ratio in the lower stories. The building typically has a simple rectangular floor plan with a breadth of over 6 meters and a length between 10 to 16 meters. The substructure uses shallow foundation with stones, and the superstructure is built with locally available clay burnt brick and mud mortar. The design is supported by three walls, two external walls, and one spine wall in the middle. In the upper story, the spine wall is sometimes replaced by a timber column frame system for creating a bigger continuous space. Wood joists uphold the floors and rooftop, over which wooden sheets or boards with a thick layer of mud topping are applied. The rooftop is typically doubly pitched and covered with traditional stone in the past, but nowadays, they are replaced by CGI sheets to make it waterproof. The brick masonry wall’s typical thickness is about 60 cm and consists of a bricklayer in mud mortar and timber planks and beams. During fieldwork, general information about the building, such as its length, breadth, height, number of stories, the thickness of the masonry wall, position and size of doors and windows, dimension of timber beams and columns, and material properties, was measured. The dead and live load in the building model is applied based on IS 875-1 (1987) and IS 875-22 (1987) codes.[2] The load of the timber staircase is calculated manually, and its loads are distributed to the supporting wall. The mechanical properties of brick, mortar, and wallet are taken from previous literature [11]. The old Newari building and corresponding plan, front and side elevation, and sectional view of the studied building are presented in Figures 2 and 3. The structural and geometrical properties of the case study building are summarized in Table 1. Figure 2. Old Newari building S o u r c e: Photo by K. Chapagain, H. Chaulagain a c Figure 3. Details of studied building structure: a - plan; b - front and side elevation; c - cross section S o u r c e: made by K. Chapagain, H. Chaulagain Table 1 Geometrical and structural properties Description Properties Description Properties Area of building 14.8 m×6.70 m Unit weight of brick in mud mortar (ϒ) 17.68 kN/m3 Building Height 9.06 m Modulus of elasticity (E) 509 N/mm2. Floor height GF = 2.30 m, FF = 2.16 m, SF = 1.93 m, TF = 2.68 m (at attic) Modulus of elasticity of Sal (E) 12600 N/mm2 Earthquake Zone V Shear modulus (G) 204 N/mm2 Subsoil type II Unit weight of mud-topped 1.47 kN/m3 Timber column 0.14 m×0.14 m Imposed load for Floor 2 kN/m3 Timber beam 0.14 m×0.10 m Imposed load for roof 1 kN/m3 Slab thickness 0.125 m Unit weight of Sal (ϒ) 8.03kN/m3 Wall thickness 0.60 m Poisson’s ratio (ν) 0.25 S o u r c e: made by K. Chapagain, H. Chaulagain 2.2. Determination of compressive strength of brick units of building model The old Newari building that exists today was constructed 265 years ago in 1814 B.S and is still being used as a residential space. Despite being exposed to various earthquakes in the past and recent times, the building remains in good usable condition. The masonry walls of the building are made of brick units constructed using local cohesive soil without the addition of any binding materials. In order to assess the strength of the bricks, a sample was taken from the building and tested using a Compression Testing Machine (CTM), and the results of this experiment are provided in Table 2. Additionally, Figure 4 depicts the testing process for the brick units. Figure 4. Testing of brick samples in lab S o u r c e: photo by K. Chapagain, H. Chaulagain 2.3. Seismic Input The ground motion parameters of displacement, velocity, and acceleration can occur separately or in combination. Acceleration is usually the measured quantity, and the other parameters are derived from it. However, due to limitations in technology and instrument setup, there is a lack of precise earthquake data. To meet the research objectives, appropriate time history data must be arranged. This study considers three recorded earthquakes, which are presented in Table 3. The peak ground acceleration (PGA) has been scaled to an interval of 0.05 to 1 g. The El Centro, Gorkha, and Kobe earthquakes are analyzed in two orthogonal components in the x- and y-directions, as their magnitudes, fault distances, and source mechanisms correspond to the seismic hazard at the study location. Figure 5 shows the earthquakes examined in this study. Table 3 Peak ground acceleration used for the dynamic analysis Name of earthquake Peak Ground Acceleration (PGA) Kobe earthquake 0.379 g El Centro earthquake 0.365 g Gorkha earthquake 0.4 g S o u r c e: made by K. Chapagain, H. Chaulagain a b c Figure 5. Time history data: a - Kobe earthquake; b - El-Centro earthquake; c - Gorkha earthquake S o u r c e: made by K. Chapagain, H. Chaulagain 2.4. Linear time history analysis The analysis of masonry structures using nonlinear methods is a complicated and time-consuming process. Therefore, linear analysis, which is a simpler approach, is more commonly used. This method involves studying the structural behavior within the linear range of the stress-strain curve, assuming the brick masonry as a homogeneous material. Many researchers utilize linear time history analysis to determine the real performance of the structure. In time history analysis, loading and response history is analyzed in progressive time increases using a step-by-step technique. It is assumed that the structural characteristics remain constant and the structure behaves linearly throughout the loading history. Each natural mode of vibration is estimated as a function of the building period for a given time history and damping, and is expressed in terms of pseudo-spectral acceleration, displacement, and velocity. 2.5. Damage state criteria and fragility analysis The study of a structure's behavior can be achieved by examining damage thresholds, also known as limit states, which represent the point at which different levels of damage occur. Various researchers have recommended different damage states, based on criteria such as drift ratio, yield displacement, and ultimate displacement of the structure, for example in [12] established light, moderate, and severe damage levels based on maximum drift ratio, while Dumova-Javanoska [13] proposed five damage levels (none, minor, moderate, severe, and collapse) based on damage index. Kircil and Polat [14] developed yielding and collapse damage levels for studying the performance of existing structures, while Jiang et al. [15] suggested maximum inter-storey drift ratio and global damage index for fragility assessment. Ahmad [16] focused on slight, moderate, extensive, and incipient damage levels to study reinforced concrete structures in the Himalayan region. Lagomarsino and Giovinazzi [17] employed four damage grades - slight damage (0.7 dy), moderate damage (1.5 dy), extensive damage (0.5 (dy + du)), and complete damage (du) - by considering ultimate (du) and yield displacement (dy) for the fragility analysis of existing structures. After reviewing the limit states proposed by various researchers, it was found that the most commonly adopted limit states are slightly damage, moderate damage, extensive damage, and complete damage. Therefore, Lagomarsino and Giovinazzi’s [17] four limit states were used in this study to construct a fragility curve that describes the performance level of the study building. Fragility curves are typically generated through a fragility analysis of structures. Specifically, they are obtained by deriving a probability of failure relation from the following expression: P f ln Sd / Sc . β Where, (…) represents a standard cumulative normal distribution function, Sd and Sc are the demand displacement and medium of damage state. For this study, the demand displacement of the building structure was determined through linear dynamic analysis using three different ground motions. The medium damage states were determined using the damage grade proposed by Lagomarsino & Giovinazzi [17]. The total uncertainty is represented by the log standard deviation, denoted by the symbol β, as per HAZUS-MH-MR4.[3] 3. Finite element modelling 3.1. Structural Modeling There are two main approaches to model masonry structures: micro modelling and macro modelling. In micro modelling, masonry is considered as a single-phase material, while macro modelling involves modelling the masonry structure as two or three phase materials. However, the macro modelling approach cannot address the mortar joints acting as a plane of weakness. Therefore, this study adopts the micro modelling approach due to its higher level of accuracy and simplified methodology. Figure 6 presents the different modelling approaches, including macro modelling, simplified micro modelling, and detailed macro modelling with two-phase and three-phase materials. Brick Element Mortar Element a b c Figure 6. Masonry modeling strategies: a - macro-modeling; b - simplified micro-modeling; c - detailed micro-modeling S o u r c e: Asteris et al. [18] 3.2. Foundation The strip foundation of the old Newari traditional building is constructed with larger stones at the base and has a depth of at least 175 cm for buildings with three to four stories. The construction follows a stepped fashion and has a width greater than 1 m. 3.3. Masonry walls The walls are made of mud mortar and unreinforced brick masonry, typically consisting of three layers of bricks in the vertical direction. The brick units are handmade using locally available soil for the mortar. 3.4. Floor System The traditional Newari building’s flooring is typically constructed with timber material. Wooden or timber joists with an average dimension of 0.10 m width and 0.14 m depth and a center-to-center dimension of 0.35 m to 0.45 m are used to support the floor from party wall to party wall. The floor is supported by closely spaced timber joists with a layer of wooden planks. The subfloor is finished with a mud-topped layer that is 10 cm thick. 3.5. Roof system In the past, the roof structure of the building was made of stone slabs and was supported by timber purlins and rafters. However, nowadays, the stone slabs have been replaced by CGI sheets. The rafters and purlins are supported by the brick masonry walls. 3.6. Masonry construction Masonry structures are characterized by continuous bearing walls instead of framed structures. When subjected to vertical loads, these walls exhibit excellent mechanical behavior and high resistance to impact or accidental loads. However, when subjected to horizontal loads such as earthquakes, masonry structures tend to have low stability due to the low tensile strength of masonry materials. Thus, in masonry structures, all walls contribute significantly to structural function. It should be noted that masonry structures typically have structural walls with constant transverse dimensions and experience only modest compressive loads [19]. 3.7. Timber in masonry Besides using wooden ring beams at the top of load-bearing walls, timber elements can also be employed as horizontal reinforcement along the wall's height, creating a building technique known as “timber-laced masonry.” This method not only enhances the wall-to-wall connection but also provides stability through the systematic insertion of timber pieces along the wall’s height. The use of timber elements is advantageous due to their superior tensile strength. The confined masonry wall sections improve the walls' compressive strength and deformability. The timber-laced masonry technique is distinct from ring beams and has been examined separately [20]. 3.8. Modelling of contact surfaces Typically, wooden beams and columns are modeled as either fixed or hinged joints, but in reality, their behavior doesn’t match either of these assumptions. In the software SAP2000 v20[4], frame elements are represented by single center lines to model timber elements such as joists, beam-columns, and posts. These center lines come into contact with adjacent masonry walls, which are modeled as thick shell elements. In actual designs, the surface of wooden elements contacts the adjacent masonry wall, and this contact issue is resolved by introducing link elements between the wooden elements and the surface of the thick shell element. When the joint moment of the rafter and masonry is fixed, a two-point link must be applied to bring it closer to a simple support. To satisfy bending moments closer to pin joints, two-point link elements are used during modeling. 3.9. SAP 2000 v 20 Computers and Structures developed the SAP2000 v20 software which offers a user-friendly interface for modeling, analysis, design, and reporting. Users can customize window layouts and toolbar configurations. As a finite element program, SAP2000 v20 has gained popularity for its versatility in designing and analyzing various structures such as buildings, bridges, dams, and industrial plants. Its practical and object-based modeling environment allows for easy to complex calculations in 2D and 3D models. SAP2000 v20 also provides a wide range of structural analysis techniques, including linear and nonlinear analysis, static and dynamic analysis, seismic analysis with ground excitations, response spectrum analysis, and other types of dynamic analysis under time-varying constraining conditions. A FEM model was created using SAP2000 v20 to evaluate the response of the structure to different levels of seismic activity. The isotropic elastic behavior was assumed, ignoring the effect of mortar joints as planes of weakness. These assumptions were useful in predicting low-level stress deformations but not higher-level stress deformations that result from nonlinear material behavior and local failure. Material models based on average properties and ignoring the effect of mortar joints were used, but including the possibility of local failure [21]. Brick masonry walls were modeled using isotropic surface members, i.e. shell elements, and wooden joists, beams, and posts were represented by isotropic linear members, i.e. frame elements [18]. The building model created in SAP2000 v20 is depicted in Figure 7. Figure 7. Building model in Sap 2000 v20 S o u r c e: made by K. Chapagain, H. Chaulagain 4. Results and discussion 4.1. Stress level in structure Table 4 shows the stress contour map of the building model generated by the finite element software SAP2000 v20 under the load combination of DL+LL+THx and DL+LL+Thy. The highest stress values were observed at the openings and the base of the building model, while the tensile stress was concentrated at the gabion. At a PGA of 0.30 in the three different considered earthquakes, the maximum compression stress (S11), stress in the perpendicular direction (S22), and shear stress (S12) were 0.564 MPa, 1.313 MPa, and 0.988 MPa respectively. Conversely, the maximum tension stress (S11), stress in the perpendicular direction (S22), and shear stress (S12) were 3.287 MPa, 3.436 MPa, and 2.0 MPa, respectively. Based on the permissible allowable stress of a masonry structure for compression, tension, and shear, the building model is safe in compression but not in tension and shear. The results also indicate that the structure performs better under loading in the y direction. Figure 8 shows the maximum compression shear stress (S11 and S12) in the building model. Table 4 Stress on the building due to three different earthquakes MPa El Centro Gorkha Kobe Combination Type of stress S11 S22 S12 S11 S22 S12 S11 S22 S12 C 0.434 1.294 0.673 0.469 1.302 0.646 0.336 1.228 0.453 DL+LL+THx T 1.229 1.368 2.611 1.023 1.272 2.237 2.938 3.436 1.57 C 0.564 1.313 0.988 0.378 1.304 0.576 0.491 1.251 0.872 DL+LL+THy T 0.972 1.397 1.115 1.682 1.475 2.321 3.287 2.092 1.90 S o u r c e: made by K. Chapagain, H. Chaulagain a b Figure 8. Maximum shear stress: a - S11; b - S12 in the building in compression (S12) S o u r c e: made by K. Chapagain, H. Chaulagain 4.2. Fragility analysis Fragility curves are useful tools for structural engineers and experts to assess the seismic vulnerability of buildings. In this study, fragility curves were generated for four damage states for three earthquakes: El Centro, Kobe, and Gorkha. The peak ground acceleration (PGA) values ranged from 0.10g to 1g with an interval of 0.05g, and the probability of failure for the structure was determined. From Figure 9, it is evident that the building model has a higher probability of failure for slight, moderate, extensive, and collapse damage levels in the Kobe earthquake at a PGA of 0.30g than in the El Centro and Gorkha earthquakes. Previous studies have highlighted a peak ground acceleration of 0.40g for Pokhara with a 10 % probability of exceedance in 50 years [22]. Therefore, the probability of failure at a PGA of 0.30 to 0.40 is significant in this study. Figure 9. Fragility Curve of Old Newari Building for various Damage States at El Centro Earthquake S o u r c e: made by K. Chapagain, H. Chaulagain 4.3. Inter-storey drift Based on the results of the linear static analysis, it can be observed that the building model exceeds the standard drift limit proposed by the code (FEMA, 2008)4 in all three earthquakes - Kobe, El Centro, and Gorkha. The displacement of the building is found to be the highest in Kobe earthquake, followed by El Centro and Gorkha earthquakes. Additionally, the displacement of the structure does not meet the prescribed limit, indicating its vulnerability in terms of displacement (Figure 10). This may be attributed to various factors, including the parameters associated with the time history function such as frequency content and duration (Table 5). 0 10 20 30 40 50 60 0.0 0.2 0.4 0.6 0.8 1.0 Horizontal displacement (mm) Drift (%) a b Figure 10. Storey displacement and drift of building structure in different earthquakes: a - Storey displacement; b - Storey drift S o u r c e: made by K. Chapagain, H. Chaulagain Table 5 Probability of failure at PGA = 0.3g for Centro, Gorkha and Kobe Earthquake Earthquake Slight Moderate Extensive Complete State of damage El Centro 99.94 98.05 72.26 39.15 Extensive Gorkha 99.85 96.19 61.78 28.56 Extensive Kobe 99.97 98.79 78.46 46.94 Extensive S o u r c e: made by K. Chapagain, H. Chaulagain 5. Conclusion This research paper presents a case study of an existing 265-year-old Newari building made of brick masonry in mud mortar. In the numerical analysis, a masonry wall is modeled as a thick shell homogeneous element and timber is modeled as isotropic linear members frame element. Three earthquakes, namely El Centro, Kobe, and Gorkha earthquakes, with different peak ground acceleration values are considered as seismic input parameters. Based on the stress level and the fragility status of the building structure, the following conclusions are drawn: 1. The stress level of the building structure is within the allowable permissible limit in compression, while the tension and shear stress levels exceed the allowable limit, indicating the vulnerability of the structure to shear and tension. 2. The probability of failure of the building is higher in Kobe earthquake at the same peak ground acceleration value as compared to El Centro and Gorkha earthquakes. This may be due to the variation in model frequencies and predominant frequencies of the ground motion. 3. The displacement of the building model is maximum in Kobe earthquake followed by El Centro and Gorkha earthquakes, and the displacement of the structure is not within the same limit. Thus, the studied 4 Federal Emergency Management Agency (FEMA). (2008). Disaster Program Information. Washington, DC: FEMA. building is vulnerable in displacement parameter, which may be attributed to the parameters associated with time history function like frequency content and duration. Moreover, the building model has higher interstory drift level as compared to the standard drift limit in all three considered earthquakes.
×

About the authors

Krishna Chapagain

Pokhara University

Email: krishnachapagain1234567@gmail.com
ORCID iD: 0009-0006-7964-8601

Post Graduate Student, M.Sc. in Structural Engineering, School of Engineering

Pokhara, Federal Democratic Republic of Nepal

Hemchandra Chaulagain

Pokhara University

Author for correspondence.
Email: hchaulagain@gmail.com
ORCID iD: 0000-0002-9483-5652

Ph.D., Associate Professor, School of Engineering

Pokhara, Federal Democratic Republic of Nepal

References

  1. Ghimire N., Chaulagain H. Seismic vulnerability assessment of reinforced concrete school building in Nepal. Asian Journal of Civil Engineering. 2021;22:249-262. https://doi.org/10.1007/s42107-020-00311-6
  2. Gautam D., Rodrigues H., Bhetwal K., Neupane, P., Sanada, Y. Common structural and construction deficiencies of Nepalese buildings. Innovation Infrastructure Solution. 2016;1(1). https://doi.org/10.1007/s41062-016-0001-3
  3. Adhikari R.K., D’Ayala D. 2015 Nepal earthquake: seismic performance and post-earthquake reconstruction of stone in mud mortar masonry buildings. Bulletin of Earthquake Engineering. 2020;18:3863-3896. https://doi.org/10.1007/s10518-020-00834-y
  4. Nazeer T.N., Job T. Behaviour and strength assessment of masonry prism. Case Studies in Construction Materials. 2017;7:11-18. https://doi.org/10.1016/j.cscm.2017.12.007
  5. Thomas J. Concrete block reinforced masonry wall panels subjected to out-of-plane monotonic lateral loading. In Proceedings of National Conference on Recent Advances in Structural Engineering. Hyderabad, India, 2006. p. 123-129.
  6. Varum H., Tarque N., Silveira D., Camata G., Lobo B., Blondet M., Costa A. Structural behaviour and retrofittingof adobe masonry buildings. In M.F. Ruiz, F.R. López (Eds.), Structural rehabilitation of old buildings. Springer, Berlin, Heidelberg. 2014. p. 37-75.
  7. Costigan A., Pavía S., Kinnane O. An experimental evaluation of prediction models for the mechanical behavior of unreinforced, lime-mortar masonry under compression. Journal of Building Engineering. 2015;4:283-294. https://doi.org/10.1016/j.jobe.2015.10.001
  8. Parajuli R.R., Kiyono J. Ground motion characteristics of the 2015 Gorkha earthquake, survey of damage to stonemasonry structures and structural field tests. Frontiers in Built Environment. 2015;123. https://doi.org/10.3389/fbuil.2015.00023
  9. Endo Y., Yamaguchi K., Hanazato T., Mishra C. Characterisation of mechanical behaviour of masonry composedof fired bricks and earthen mortar. Engineering Failure Analysis. 2020;109:104280. https://doi.org/10.1016/j.engfailanal. 2019.104280
  10. Parajuli R.R., Furukawa A., Gautam D. Experimental characterization of monumental brick masonry in Nepal. Structures. 2020;28:1314-1321. https://doi.org/10.1016/j.istruc.2020.09.065
  11. Parajuli H.R. Determination of mechanical properties of the Kathmandu World Heritage brick masonry buildings. In Proceedings of the World Conference on Earthquake Engineering. Kyoto, Japan; 2012.
  12. Akkar S., Sucuoglu H., Yakut A., Eeri М., Yakut A. Displacement-based fragility functions for low and mid-rise ordinary concrete buildings. Earthquake Spectra. 2005;21(4):901-927. https://doi.org/10.1193/1.2084232
  13. Dumova-Jovanoska E. Fragility curves for reinforced concrete structures in Skopje region. Soil Dynamics and Earthquake Engineering. 2000;19(6):455-466. https://doi.org/10.1016/S0267-7261(00)00017-8
  14. Kircil M., Polat Z. Fragility analysis of mid-rise R/C frame buildings. Engineering Structures. 2006;28(9):1335- 1345. https://doi.org/10.1016/j.engstruct.2006.01.004
  15. Jiang H., Lu X., Chen L. Seismic Fragility Assessment of RC Moment-Resisting Frame Designed According to Current Chinese Seismic Design Code. Journal of Asia Architecture and Building Engineering. 2012;11(1):153-160. https://doi.org/10.3130/jaabe.11.153
  16. Ahmad N. Fragility Functions and Loss Curves for Deficient and Haunch-Strengthened RC Frames. Journal of Earthquake Engineering. 2019;26(1):1-30. https://doi.org/10.1080/13632469.2019.1698478
  17. Lagomarsino S., Giovinazzi S. Macroseismic and mechanical models for the vulnerability and damage assessment of current buildings. Bulletin of Earthquake Engineering. 2006;4(4):415-443. https://doi.org/10.1007/s10518-006-9024-z
  18. Asteris P.G., Chronopoulos M.P., Chrysostomou C.Z., Varum H., Plevris V., Kyriakides N., Silva V. Seismic vulnerability assessment of historical masonry structural systems. Engineering Structures. 2014;62-63:118-134. https://doi.org/10.1016/j.engstruct.2014.01.031
  19. Dipasquale L., Rovero L., Fratini F. Ancient stone masonry constructions. In: Nonconventional and Vernacular Construction Materials. Florence, Italy, 2020. p. 403-435. https://doi.org/10.1016/B978-0-08-102704-2.00015-9
  20. Ortega J., Vasconcelos G., Rodrigues H., Correia M.A vulnerability index formulation for the seismic vulnerability assessment of vernacular architecture. Engineering Structures. 2019;196(11):109381. https://doi.org/10.1016/j.engstruct.2019.109381
  21. Tzamtzis A.D., Asteris P.G. Finite element Analysis of Masonry Structures: Part-1. Review of previous Work. In: Proceedings of the Ninth North American Masonry Conference. Clemson, South Carolina, USA; 2003.
  22. Parajuli H.R. Dynamic Analysis of low strength masonry houses based on the site-specific earthquake ground motion. PhD Thesis, Kyoto University; 2009.