<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE root>
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" article-type="research-article" dtd-version="1.2" xml:lang="en"><front><journal-meta><journal-id journal-id-type="publisher-id">RUDN Journal of Medicine</journal-id><journal-title-group><journal-title xml:lang="en">RUDN Journal of Medicine</journal-title><trans-title-group xml:lang="ru"><trans-title>Вестник Российского университета дружбы народов. Серия: Медицина</trans-title></trans-title-group></journal-title-group><issn publication-format="print">2313-0245</issn><issn publication-format="electronic">2313-0261</issn><publisher><publisher-name xml:lang="en">Peoples’ Friendship University of Russia named after Patrice Lumumba (RUDN University)</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">30537</article-id><article-id pub-id-type="doi">10.22363/2313-0245-2022-26-1-62-68</article-id><article-categories><subj-group subj-group-type="toc-heading" xml:lang="en"><subject>Physiology</subject></subj-group><subj-group subj-group-type="toc-heading" xml:lang="ru"><subject>Физиология</subject></subj-group><subj-group subj-group-type="article-type"><subject>Research Article</subject></subj-group></article-categories><title-group><article-title xml:lang="en">The rabbits retina functional state after exposure to low-frequency ultrasound: electroretinogram indicators analysis</article-title><trans-title-group xml:lang="ru"><trans-title>Функциональное состояние сетчатки кроликов после воздействия низкочастотного ультразвука: анализ показателей электроретинограммы</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-0541-3248</contrib-id><name-alternatives><name xml:lang="en"><surname>Vafiev</surname><given-names>Aleksander S.</given-names></name><name xml:lang="ru"><surname>Вафиев</surname><given-names>А. С.</given-names></name></name-alternatives><email>a.s.vafiev@gmail.com</email><xref ref-type="aff" rid="aff1"/><xref ref-type="aff" rid="aff2"/></contrib></contrib-group><aff-alternatives id="aff1"><aff><institution xml:lang="en">Bashkir State Medical University</institution></aff><aff><institution xml:lang="ru">Башкирский государственный медицинский университет</institution></aff></aff-alternatives><aff-alternatives id="aff2"><aff><institution xml:lang="en">CJSC «Optimedservice»</institution></aff><aff><institution xml:lang="ru">ЗАО «Оптимедсервис»</institution></aff></aff-alternatives><pub-date date-type="pub" iso-8601-date="2022-03-21" publication-format="electronic"><day>21</day><month>03</month><year>2022</year></pub-date><volume>26</volume><issue>1</issue><issue-title xml:lang="en">PHYSIOLOGY</issue-title><issue-title xml:lang="ru">ФИЗИОЛОГИЯ</issue-title><fpage>62</fpage><lpage>68</lpage><history><date date-type="received" iso-8601-date="2022-03-21"><day>21</day><month>03</month><year>2022</year></date></history><permissions><copyright-statement xml:lang="en">Copyright ©; 2022, Vafiev A.S.</copyright-statement><copyright-statement xml:lang="ru">Copyright ©; 2022, Вафиев А.С.</copyright-statement><copyright-year>2022</copyright-year><copyright-holder xml:lang="en">Vafiev A.S.</copyright-holder><copyright-holder xml:lang="ru">Вафиев А.С.</copyright-holder><ali:free_to_read xmlns:ali="http://www.niso.org/schemas/ali/1.0/"/><license><ali:license_ref xmlns:ali="http://www.niso.org/schemas/ali/1.0/">http://creativecommons.org/licenses/by/4.0</ali:license_ref></license></permissions><self-uri xlink:href="https://journals.rudn.ru/medicine/article/view/30537">https://journals.rudn.ru/medicine/article/view/30537</self-uri><abstract xml:lang="en"><p style="text-align: justify;">Relevance. Currently, several groups of scientists are working on the implementation of low-frequency ultrasound in surgery of the retina and vitreous body. But there are not enough articles on the study of the functional activity of the retina when exposed to this type of energy. Electrophysiological research methods make it possible to analyze and evaluate the safety, effectiveness of surgical interventions, the effect of new drugs at the level of neurons and visual pathways. The electroretinography method makes it possible to record the bioelectrical activity of retinal neurons during light stimulation during dark and light adaptation. The aim of the study is to carry out a comparative analysis of the aand b-wave indices of the rabbit electroretinogram after experimental removal of the vitreous body using low-frequency ultrasound and mechanical action. Materials and Methods. Experiments were carried out in two groups of Chinchilla rabbits (n = 40). In the experimental group, surgery to remove the vitreous body was performed using low-frequency ultrasound, in the control group a fragmentator with guillotine mechanism was used. Before and after the surgery (1, 7, 14, 30 days) an electroretinogram was recorded, the parameters of the amplitude and latency of the aand b-waves were measured. Results and Discussion. In both groups, a sharp decrease in all parameters was observed on day 1. Later, on the 7th day, the dynamics of the latency of aand b-waves slightly decreased than the preoperative values. On the 14th day after the exposure, the amplitude and peak latency of the aand bwaves in both groups remained at the same level as on the 7th day. On the 30th day, the indicators increased, which indicates the restoration of the functions of photoreceptors and Mueller cells in both groups. There were no statistically significant differences between the study groups at all periods of the study. Conclusion. The use of low-frequency ultrasound for vitreous removal can be considered safe and has prospects for further development and application.</p></abstract><trans-abstract xml:lang="ru"><p style="text-align: justify;">Актуальность. В настоящее время несколькими группами ученых ведутся разработки по внедрению низкочастотного ультразвука в хирургию сетчатки и стекловидного тела, но нет достаточного количества работ по изучению функциональной активности сетчатки при воздействии данного вида энергии. Электрофизиологические методы исследования позволяют анализировать и оценивать безопасность, эффективность хирургических вмешательств, действие новых лекарственных средств на уровне нейронов и проводящих путей. Метод электроретинографии позволяет регистрировать биоэлектрическую активность нейронов сетчатки во время стимуляции светом при темновой и световой адаптации. Цель. Провести сравнительный анализ показателей aи bволны электроретинограммы кролика после экспериментального удаления стекловидного тела с помощью низкочастотного ультразвука и механического воздействия. Материал и методы. Были проведены эксперименты в двух группах кроликах породы Шиншилла (n=40). В экспериментальной группе хирургическое вмешательство по удалению стекловидного тела проводилось с помощью низкочастотного ультразвука, в контрольной группе применялся фрагментатор с гильотинным механизмом. До и после операции (1, 7, 14, 30 сутки) проводилась запись электроретинограммы, измерялись параметры амплитуды и латентности аи bволны. Результаты и обсуждение. В обеих группах на 1 сутки наблюдалось резкое снижение всех параметров. В дальнейшем, на 7 сутки динамика латентности aи bволн несколько снижалась по сравнению с дооперационными значениями. На 14 суткам после воздействия амплитуда и пиковая латентность аи bволн в обеих группах оставалось на том же уровне что и на 7 сутки. На 30 сутки показатели возрастали, что говорит о восстановлении функций фоторецепторов и клеток Мюллера в обеих группах. Статистических значимых различий между исследуемыми группами на всех сроках исследования не выявлено. Выводы. Применение низкочастотного ультразвука для удаления стекловидного тела может считаться безопасным и имеет перспективы для дальнейшего развития и применения.</p></trans-abstract><kwd-group xml:lang="en"><kwd>electroretinogram</kwd><kwd>low-frequency ultrasound</kwd><kwd>retina</kwd></kwd-group><kwd-group xml:lang="ru"><kwd>электроретинограмма</kwd><kwd>низкочастотный ультразвук</kwd><kwd>сетчатка</kwd></kwd-group><funding-group/></article-meta></front><body></body><back><ref-list><ref id="B1"><label>1.</label><citation-alternatives><mixed-citation xml:lang="en">Charles S, Calzada J, Wood B. Vitreous Microsurgery. Lippincott Williams &amp; Wilkins, a Wolters Kluwer business. 2011. 259 p.</mixed-citation><mixed-citation xml:lang="ru">Charles S., Calzada J., Wood B. Vitreous Microsurgery // Lippincott Williams &amp; Wilkins, a Wolters Kluwer business. 2011. 259 p.</mixed-citation></citation-alternatives></ref><ref id="B2"><label>2.</label><citation-alternatives><mixed-citation xml:lang="en">Saxena S, Meyer CH, Ohji M, Akduman L. Vitreoretinal surgery. London: Jaypee Brothers Medical Publishers. 2012. 442 p.</mixed-citation><mixed-citation xml:lang="ru">Saxena S., Meyer C.H., Ohji M., Akduman L. Vitreoretinal surgery // London: Jaypee Brothers Medical Publishers. 2012. 442 р.</mixed-citation></citation-alternatives></ref><ref id="B3"><label>3.</label><citation-alternatives><mixed-citation xml:lang="en">Ilyukhin ОЕ, Frolov МА, Ignatenko КV. Functional results of surgical treatment of retinal detachment. RUDN Journal of Medicine. 2020:24(2):156—162. doi: 10.22363/2313-0245-2020-24-2-156-162</mixed-citation><mixed-citation xml:lang="ru">Ильюхин О.Е., Фролов М.А., Игнатенко К.В. Функциональные результаты хирургического лечения отслойки сетчатки // Вестник Российского университета дружбы народов. Серия: Медицина. 2020. Т. 24. № 2. С. 156-162. doi: 10.22363/23130245-2020-24-2-156-162</mixed-citation></citation-alternatives></ref><ref id="B4"><label>4.</label><citation-alternatives><mixed-citation xml:lang="en">Khalimov TA. Features of angiogenesis in eye diseases. RUDN Journal of Medicine. 2021;25(2):106—113. doi: 10.22363/23130245-2021-25-2-106-113</mixed-citation><mixed-citation xml:lang="ru">Халимов Т.А. Особенности ангиогенеза при заболеваниях глаз // Вестник Российского университета дружбы народов. Серия: Медицина. 2021. Т. 25. № 2. С. 106-113. doi: 10.22363/2313-02452021-25-2-106-113</mixed-citation></citation-alternatives></ref><ref id="B5"><label>5.</label><citation-alternatives><mixed-citation xml:lang="en">Pavlidis M. Two-Dimensional Cutting (TDC) Vitrectome: In vitro flow assessment and prospective clinical study evaluating core vitrectomy efficiency versus standard vitrectome. Hindawi Journal of Ophthalmology. 2016:1—6. doi: 10.1155/2016/3849316</mixed-citation><mixed-citation xml:lang="ru">Pavlidis M. Two-Dimensional Cutting (TDC) Vitrectome: In vitro flow assessment and prospective clinical study evaluating core vitrectomy efficiency versus standard vitrectome // Hindawi Journal of Ophthalmology. 2016. P. 1-6. doi: 10.1155/2016/3849316</mixed-citation></citation-alternatives></ref><ref id="B6"><label>6.</label><citation-alternatives><mixed-citation xml:lang="en">Mohamed S, Claes C, Tsang CW. Review of Small Gauge Vitrectomy: Progress and Innovations. Hindawi Journal of Ophthalmology. 2017:1—9. doi: 10.1155/2017/6285869</mixed-citation><mixed-citation xml:lang="ru">Mohamed S., Claes C., Tsang C.W. Review of Small Gauge Vitrectomy: Progress and Innovations // Hindawi Journal of Ophthalmology. 2017. Р. 1-9. doi: 10.1155/2017/6285869</mixed-citation></citation-alternatives></ref><ref id="B7"><label>7.</label><citation-alternatives><mixed-citation xml:lang="en">Pastor-Idoate S, Bonshek R, Irion L, Zambrano I, Carlin P, Mironov A. et al. Ultrastructural and histopathologic findings after pars plana vitrectomy with a new hypersonic vitrector system. Qualitative preliminary report. PLOS one. 2017;4:1—16. doi: 10.1371/journal.pone.0173883</mixed-citation><mixed-citation xml:lang="ru">Pastor-Idoate S., Bonshek R., Irion L., Zambrano I., Carlin P., Mironov A. et al. Ultrastructural and histopathologic findings after pars plana vitrectomy with a new hypersonic vitrector system. Qualitative preliminary report // PLOS one. 2017. № 4. Р. 1-16. doi: 10.1371/journal.pone.0173883</mixed-citation></citation-alternatives></ref><ref id="B8"><label>8.</label><citation-alternatives><mixed-citation xml:lang="en">Aznabaev BM, Dibaev TI, Mukhamadeev TR, Vafiev AS, Shavaliev IKh. Twenty-five gauge ultrasonic vitrectomy: experimental and clinical performance analysis. Retina. 2020;7:1443—1450. doi: 10.1097/IAE.0000000000002863</mixed-citation><mixed-citation xml:lang="ru">Aznabaev B.M., Dibaev T.I., Mukhamadeev T.R., Vafiev A.S., Shavaliev I. Kh. Twenty-five gauge ultrasonic vitrectomy: experimental and clinical performance analysis // Retina. 2020. № 7. Р. 1443-1450. doi: 10.1097/IAE.0000000000002863</mixed-citation></citation-alternatives></ref><ref id="B9"><label>9.</label><citation-alternatives><mixed-citation xml:lang="en">Stanga PE, Pastor-Idoate S, Zambrano I, Carlin P, McLeod D. Performance analysis of a new hypersonic vitrector system. Plos One. 2017;12:1—15. doi: 10.1371/journal.pone.0178462</mixed-citation><mixed-citation xml:lang="ru">Stanga P.E., Pastor-Idoate S., Zambrano I., Carlin P., McLeod D. Performance analysis of a new hypersonic vitrector system // Plos One. 2017. № 12. Р. 1-15. doi: 10.1371/journal.pone.0178462</mixed-citation></citation-alternatives></ref><ref id="B10"><label>10.</label><citation-alternatives><mixed-citation xml:lang="en">Wuchinich D. Ultrasonic vitrectomy instrument. Physics Procedia. 2015;63:217—222. doi: 10.1016/j.phpro.2015.03.035</mixed-citation><mixed-citation xml:lang="ru">Wuchinich D. Ultrasonic vitrectomy instrument // Physics Procedia. 2015. № 63. Р. 217-222. doi: 10.1016/j.phpro.2015.03.035</mixed-citation></citation-alternatives></ref><ref id="B11"><label>11.</label><citation-alternatives><mixed-citation xml:lang="en">Aznabaev BM, Dibaev TI, Mukhamadeev TR, Vafiev AS, Shavaliev IKh. Ultrasonic vitrectomy: performance evaluation in experimental and clinical conditions. Practical Medicine. 2018; 6(4):56—62.</mixed-citation><mixed-citation xml:lang="ru">Азнабаев Б.М., Дибаев Т.И., Мухамадеев Т.Р., Вафиев А.С., Шавалиев И.Х. Ультразвуковая витрэктомия: исследование скорости удаления стекловидного тела в эксперименте и клинике // Практическая медицина. Т. 16. № 4. С. 56.</mixed-citation></citation-alternatives></ref><ref id="B12"><label>12.</label><citation-alternatives><mixed-citation xml:lang="en">Aznabaev BM, Dibaev TI, Mukhamadeev TR, Rakhimov AF. Experimental study of the performance of an ultrasound vitreotome. Cataract and refractive surgery. 2017;17(2):48—51.</mixed-citation><mixed-citation xml:lang="ru">Азнабаев Б.М., Дибаев Т.И., Мухамадеев Т.Р., Рахимов А.Ф. Экспериментальное исследование производительности ультразвукового витреотома // Катарактальная и рефракционная хирургия. 2017. Т. 17. № 2. C. 48-51.</mixed-citation></citation-alternatives></ref><ref id="B13"><label>13.</label><citation-alternatives><mixed-citation xml:lang="en">Zueva MV. Fundamental ophthalmology: the role of electrophysiological research. Bulletin of ophthalmology. 2014;6:28—29.</mixed-citation><mixed-citation xml:lang="ru">Зуева М.В. Фундаментальная офтальмология: роль электрофизиологических исследований // Вестник офтальмологии. 2014. № 6. С. 28-29.</mixed-citation></citation-alternatives></ref><ref id="B14"><label>14.</label><citation-alternatives><mixed-citation xml:lang="en">Mukhamadeev TR, Ahmadeev RR. Light-induced total electrical activity of retina in models of particular disorders in vivo amd in vitro. Saratov journal of medical scientific research. 2018;14(4):903—909.</mixed-citation><mixed-citation xml:lang="ru">Мухамадеев Т.Р., Ахмадеев Р.Р. Светоиндуцированная суммарная электрическая активность сетчатки при моделировании некоторых патологических процессов in vivo и in vitro // Саратовский научно-медицинский журнал. 2018. Т. 14. № 4. С. 903-909.</mixed-citation></citation-alternatives></ref><ref id="B15"><label>15.</label><citation-alternatives><mixed-citation xml:lang="en">Koshelev DI. Correlation of parameters of electroretinogram, axial length of the eye and visual acuity in emmetropia in humans. PhD Thesis. St. Petersburg. 2004. 20 p.</mixed-citation><mixed-citation xml:lang="ru">Кошелев Д.И. Корреляции параметров электроретинограммы, аксиальной длины глаза и остроты зрения при эмметропии у человека // Автореф. дис. канд. биол. наук.- Санкт-Петербург. 2004. 20 с.</mixed-citation></citation-alternatives></ref><ref id="B16"><label>16.</label><citation-alternatives><mixed-citation xml:lang="en">Kulikov AN, Sosnovskiy SV, Nikolaenko EN. Analysis of the dynamics of retinal and optic nerve electrogenesis after vitrectomy for complicated cataract surgery. Ophthalmologicheskie vedomosti. 2018;11(3):34—47. doi: 10.17816/OV11334-47</mixed-citation><mixed-citation xml:lang="ru">Куликов А.Н., Сосновский С.В., Николаенко Е.Н. Анализ динамики электрогенеза сетчатки и зрительного нерва после витрэктомии по поводу осложнённой хирургии катаракты // Офтальмологические ведомости. 2018. Т. 11. № 3. С. 34-47. doi: 10.17816/OV11334-47</mixed-citation></citation-alternatives></ref><ref id="B17"><label>17.</label><citation-alternatives><mixed-citation xml:lang="en">Akhmadeev RR, Timerbulatov IF, Koshelev DI, Evtushenko EM, Timerbulatova MF. Critical Frequency of Flicker Merging and Visual Potentials under Computer Load. RUDN Journal of Medicine. 2019;23(2):178—186. doi: 10.22363/2313-0245-201923-2-178-186</mixed-citation><mixed-citation xml:lang="ru">Ахмадеев Р.Р., Тимербулатов И.Ф., Кошелев Д.И., Евтушенко Е.М., Тимербулатова М.Ф. Критическая частота слияния мельканий и зрительные вызванные потенциалы при компьютерной нагрузке // Вестник Российского университета дружбы народов. Серия: Медицина. 2019. Т. 23. № 2. С. 178-186. doi: 10.22363/23130245-2019-23-2-178-186</mixed-citation></citation-alternatives></ref></ref-list></back></article>
